Search For Your Exact Product Here
Product Description
The WDS electromagnet is a C-Frame, variable air gap magnetic field generation equipment with each pole being adjustable. From the excitation of the excitating power source, the field vector forms a closed loop, and a high uniform magnetic field can be generated between two poles, and the field direction is along the axial direction of pole caps. All WD electromagnets are equipped with a pair of standard replaceable pole caps made of purity iron, which can be replaced to suit to individual experiment requirements. The pure-iron structure is suitable for coils heat dissipation, and the option of cooling water system is also available for extend the operating time.
Product Description
The SB electromagnet is a double-yoke(H-Frame) , variable air gap magnetic field generation equipment with each pole being adjustable. From the excitation of the excitating power source, the field vector forms a closed loop, and a high uniform magnetic field can be generated between two poles, and the field direction is along the axial direction of pole caps. All SB electromagnets are equipped with a pair of standard replaceable pole caps made of purity iron, which can be replaced to suit to individual experiment requirements. The pure-iron structure is suitable for coils heat dissipation, and the option of cooling water system is also available for extend the operating time.
Product Description
The SBV electromagnet is a double-yoke(H-Frame) , variable air gap magnetic field generation equipment with one pole being adjustable. From the excitation of the excitating power source, the field vector forms a closed loop, and a high uniform magnetic field can be generated between two poles, and the field direction is along the axial direction of pole caps. All SBV electromagnets are equipped with a pair of standard replaceable pole caps made of purity iron, which can be replaced to suit to individual experiment requirements. The pure-iron structure is suitable for coils heat dissipation, and the option of cooling water system is also available for extend the operating time.
Product Description
Clamp Electromagnet, of which the shape is like a vice, has two magnetic poles protruding outside the coils. It is usually used to generate an in-plane magnetic field. It is suitable for special operation environments such as microscopy, probe station, the limited space, magneto-optical experiment, and magnetic mineral powder screening. The Clamp Electromagnet is basically custom-made, and can be designed and produced according to user's application conditions and magnetic field requirements.
Product Description
Multi-Pole Electromagnet is a kind of closed loop electromagnet composed of multiple caps, which is basically the Four-Pole Electromagnet, and also has the other multi-pole applications such as Five-Pole, Six-Pole, and Eight-Pole. They are mainly applied for Multi-Pole Magnetic Ring Magnetization, Radial-Direction Gradient Magnetic Field, and Rotating Magnetic Field Magnetic Guidance and etc. and they can be designed and produced according to user's individual requirements.
Product Description
Single-Pole Electromagnet is an open loop electromagnet consisting of a single pole cap. The main advantages of this electromagnet are open structure and large operating space This electromagnets are equipped with a pair of standard replaceable pole caps made of purity iron, which can be replaced to suit to individual experiment requirements. The pure-iron structure is suitable for coils heat dissipation, and the option of cooling water system is also available for extend the operating time.
The DC power supply is a bipolar constant current power supply with high stability, high accuracy, high linearity and low ripple noise;<br/> Relay-reversal direction controlled by the microprocessor with 5 options to delay time; <br/> Reversal current surge: Less than 1 mA; <br/> Three linear sweep modes including I, I-III, I-III-I quadrants; <br/> Provided with built-in RS-232 or USB port and the relative conversion port;<br/> A set of computer interface command (for RS-232 or USB port);<br/> Timing continuous trigger output during sweeping.
Programmable DC power supply is a high-performance DC power supply specially developed for scientific research and industrial applications in power automation control.<br/> This series power supply has excellent electronic characteristics such as high accuracy, precision, and stability, designed with comprehensive over-voltage and over-temperature protection circuits, resulting in higher reliability of the products, and can be used to edit voltage, current and time parameters by the host computer through the panel keyboard or through the communication interface to achieve programmable automatic testing. It is widely used in excitation of inductive loads such as electromagnets and Helmholtz coils.
High Homogeneity coil, which is composed of multi-ring coils arranged along the axial direction, includes the common coils such as Barker Coil, Braunbek Coil, Maxwell Coil, Rubens Coil, and Magnetic-Moment-Free coil. Compared with the Helmholtz coil, the combined coil features the better magnetic field homogeneity under the same diameter, the higher homogeneity and larger homogeneity volume in the effective space, and is suitable for the high-precision and large-range magnetic field needs. This design can meet any parameter customization requirements.
Single-Pole Electromagnet is an open loop electromagnet consisting of a single pole cap. The main advantages of this electromagnet are open structure and large operating space This electromagnets are equipped with a pair of standard replaceable pole caps made of purity iron, which can be replaced to suit to individual experiment requirements. The pure-iron structure is suitable for coils heat dissipation, and the option of cooling water system is also available for extend the operating time.
The three-axis Helmholtz coil is composed of 3 pairs of Helmholtz coils arranged along three orthogonal axes, which can simultaneously generate uniform magnetic fields in the direction of x-, y-, or z-axis.Helmholtz coils can be customized by through adjusting the coil diameter, required magnetic field, working time, structural requirements, and dissipation requirements (air cooling or water cooling).
Variable-Magnetic-Field Permanent Magnet is an innovative magnetic device that changes the magnetic field strength by adjusting the air gap, and which is widely used in various experiments and industrial applications that require variable magnetic fields. By combining precision mechanical design with high-performance rare earth materials, adjustable permanent magnets can flexibly adjust their magnetic field strength without the need for excitation current, providing multiple magnetic field environments to meet different application needs.
Flux-gate magnetometer is a that accurately measures weak static and low-frequency vector magnetic fields,which has the characteristics of high stability, high linearity, high-precision and full digitization. Compared with magnetic field measurement instruments based on Hall effect principle or magnetoresistance effect principle, it is the best choice for measuring weak magnetic fields. It has digital and analog signal output, and a unique CAN bus network interface suitable for multi array magnetic field testing. It is widely used in scientific research, military industry, aerospace and other departments
A vibrating sample magnetometer(VSM) is an instrument that is used to measure magnetic properties. It is also called a Foner magnetometer or M-H Curve Hysteresis Graph Test System. <br/> VSM is composed of a master device, an electromagnet, a vibrator, a
A vibrating sample magnetometer(VSM) is an instrument that is used to measure magnetic properties. It is also called a Foner magnetometer or M-H Curve Hysteresis Graph Test System. <br/> VSM is composed of a master device, an electromagnet, a vibrator, a computer. The electromagnet source, the vibrator source, the magnetic moment measuring unit and the magnetic field measuring unit which all controlled by MPU (AT89C52) constitute the instrument. The instrument communicates to the computer with the standard RS-232-C serial interface, then enhanced systematicness of the instrument and operability of the hardware. Operating functions of the special complement software is powerful and software is used conveniently.
The field air gap is adjustable in both directions, with a single yoke structure and a horizontal magnetic field direction; Standing upright and having a wide operating space, it is convenient for taking and placing samples and combining with other equipment, making it one of the most common electromagnetic magnets in magnetic research. Used for Hall effect research and magnetoresistance effect research.
The field air gap is adjustable in both directions, with a single yoke structure and a horizontal magnetic field direction; Standing upright and having a wide operating space, it is convenient for taking and placing samples and combining with other equipment, making it one of the most common electromagnetic magnets in magnetic research. Used for Hall effect research and magnetoresistance effect research.
The field air gap is adjustable in both directions, with a single yoke structure and a horizontal magnetic field direction; Standing upright and having a wide operating space, it is convenient for taking and placing samples and combining with other equipment, making it one of the most common electromagnetic magnets in magnetic research. Used for Hall effect research and magnetoresistance effect research.
The field air gap is adjustable in both directions, with a single yoke structure and a horizontal magnetic field direction; Standing upright and having a wide operating space, it is convenient for taking and placing samples and combining with other equipment, making it one of the most common electromagnetic magnets in magnetic research. Used for Hall effect research and magnetoresistance effect research.
The field air gap is adjustable in both directions, with a single yoke structure and a horizontal magnetic field direction; Standing upright and having a wide operating space, it is convenient for taking and placing samples and combining with other equipment, making it one of the most common electromagnetic magnets in magnetic research. Used for Hall effect research and magnetoresistance effect research.
The field air gap is adjustable in both directions, with a single yoke structure and a horizontal magnetic field direction; Standing upright and having a wide operating space, it is convenient for taking and placing samples and combining with other equipment, making it one of the most common electromagnetic magnets in magnetic research. Used for Hall effect research and magnetoresistance effect research.
The field air gap is adjustable in both directions, with a single yoke structure and a horizontal magnetic field direction; Standing upright and having a wide operating space, it is convenient for taking and placing samples and combining with other equipment, making it one of the most common electromagnetic magnets in magnetic research. Used for Hall effect research and magnetoresistance effect research.
The field air gap is adjustable in both directions, with a single yoke structure and a horizontal magnetic field direction; Standing upright and having a wide operating space, it is convenient for taking and placing samples and combining with other equipment, making it one of the most common electromagnetic magnets in magnetic research. Used for Hall effect research and magnetoresistance effect research.
The field air gap is adjustable in both directions, with a single yoke structure and a horizontal magnetic field direction; Standing upright and having a wide operating space, it is convenient for taking and placing samples and combining with other equipment, making it one of the most common electromagnetic magnets in magnetic research. Used for Hall effect research and magnetoresistance effect research.